Submission Guidelines           

Please note: we do NOT accept samples with the following: post-it notes, loose papers, absent email addresses, tubes with wrap-around labels (they get stuck in the automated system), screw cap tubes (they break the very expensive tips on our robot), or 0.5mL tubes.

DNA Concentration

DNA Type
DNA Size
DNA Concentration
Plasmid 3-10 kb 100 ng/ul
Plasmid >10 kb 100 ng/ul
PCR Product <1 kb 50 ng/ul
PCR Product 1-3 kb 100 ng/ul
BAC DNA 250 ng/ul

 


Note: All dilutions should be performed using water.


Primer Concentration

• Primers for sequencing plasmid DNA, PCR products, and BAC DNA should be submitted at a concentration of 10 ng/µl or 1.0 µmol

Note: All dilutions should be performed using water.


Tubes

• The facility only accepts 1.5 ml flip-top tubes
• All tubes must be labeled on the cap
• All tube labels should exactly match the DNA and primer names entered on the submission form
• The facility will not accept screw cap tubes
• The facility will not accept tubes smaller or larger than 1.5 ml tubes
• The facility will not accept tubes with wrap-around labels

Volumes

• For DNA template and primers, please submit at least 10µl per reaction
• The same DNA sample for different sequencing reactions can be placed in the same DNA tube. The same primer for different sequencing reactions can also be placed in a single primer tube.

Example: If you want to sequence DNA X with 3 different primers (3 sequencing reactions) you will need to submit a total of 3 x 10 µl = 30 µl of DNA X in a single 1.5 ml flip-top tube.